We compare simultaneous magnetograms of a solar active region taken by
the Advanced Stokes Polarimeter (ASP) and the Solar Optical Universal
Polimeter (SOUP) in 1998. In addition we compare magnetograms taken by
the La Palma Stokes Polarimeter (LPSP), the Michelson Doppler Imager
(MDI) on SOHO, and the SOUP instrument in 2000. The SOUP instrument on
the Swedish Vacuum Solar Telescope (SVST) attains the highest spatial
resolution but has the least understood calibration; the ASP on the Dunn
Solar Telescope (DST) at Sacramento Peak attains the highest magnetic
field precision. The goal of the program is to better quantify the SOUP
magnetograms and thereby study magnetic element dynamics in the
photosphere with higher precision.